AMC-752 (Bug)

Chunk load-unload loop in server caused by new IC2 energy net

Description

The new IC2 energy net introduced in 27 DEV7 can cause chunk load-unload loops on the server in some circumstances. This is most likely the result of TE lookups being made in sections of the map that aren't loaded, with those TE lookups being triggered by the unload of adjacent chunks.

Some work was already done towards fixing this problem in DEV7.3, but the problem is evidently not completely resolved because the bug is still causing significant problems in some areas of the survival map (most particularly right now for people wandering near the Dovahkiin nether base)

Further investigation is required to track down exact cause(s).

Related Issues

This issue is not related to any other issues

User Feedback

Recommended Comments

Tinytimrob
Issue Creator Current Assignee Project Manager Programming Lead

Posted

Confirmed issue

Confirming issue. Right now I'm not able to work on fixing this because I'm on vacation until second week of July.

Share this comment


Link to comment
Share on other sites
Tinytimrob
Issue Creator Current Assignee Project Manager Programming Lead

Posted

Marked issue as fixed in version SNAPSHOT (76a47b1efe96)

Fixed in r5109.

Adjacent tile notification will no longer be triggered by default when IC2 tile is added to or removed from energynet. Having this as the default behaviour is just too buggy and causes large load-unload loops in many instances.

Blocks which explicitly need the notification (which should be the minority) will now have to explicitly state this in their block constructor. Currently this is set only to the IC2 power cable, which uses the load-unload trigger for updating cable directionality.

This change may be behaviourally breaking with IC2 in some places and might warrant future patches to fix bugs caused as a result of this change.

Share this comment


Link to comment
Share on other sites
Tinytimrob
Issue Creator Current Assignee Project Manager Programming Lead

Posted

Marked issue as resolved in version Fondant 27 DEV9.5 [r5112] (5c3b764c9b92)

Resolved in 27 DEV9.5

Share this comment


Link to comment
Share on other sites

Create an account or sign in to comment

You need to be a member in order to leave a comment

Create an account

Create a new GineverAccount today. It's easy!

Register a new account

Sign In with GineverAccount 5.1

Already have an account? Sign in here.

Sign In Now
×
×
  • Create New...